2/2 way direct acting solenoid valve, NC

Direct acting 2/2-way solenoid valve of several nominal diameters for use with neutral gases and liquids. This valve is direct acting and normally closed (NC).

Valves of this design are single chamber straight through valves, with threaded tube clamp or push-fit connections at outlet and inlet.

The valve body is made of PPSU, which is suitable for hot water applications.

This valve is designed for continuous operation
(duty cycle 100%).

Electrical operating safety is achieved by using high quality materials of insulation class H.

Espresso- / High-Pressure Valves 18.00x 2/2-way direct acting NC (normally closed)

Applications

  • Saturated steam applications up to 143° C
  • Steam cleaners and ironing machines
  • Hot / cold drink dispensers (espresso machines)
  • Medical equipment
  • Industrial applications

Characteristics

  • Direct acting
  • Compact design
  • Long term performance capability
  • Suitable for food and hot water appliances
  • Works from zero pressure
  • Easy to assemble and service
  • Coil change without opening of medium circuit, coil can be mounted 4 x 90°
  • High operating safety through the use of high quality materials and 100% final testing of the products

Options

ID DN Cv-value Inlet Outlet p-Operating Coil type Voltage
mm l/min Ø mm Ø mm bar in flow direction bar against flow direction V
087714 1,5 0,9 F G 0 - 16,0 0 - 12,0 MS 40 24
087712 G G
087733 F G
087717 F F
087719 F E
087723 F F 0 - 7,5 12
087736 F F 0 - 2,5 230 / 50 Hz
087730 F F 0 - 12,0 MS 39 24
087728 F G
087724 2 1,5 G G 0 - 6,0 0 MS 40
087734 F F 0 -10,0 0 - 1,0 12
087735 F F 24
087726 2,5 2,1 F F 0 - 3,0 *) 0 - 5,0 MS 39
087727 2,5 F F 0 - 6,0 0
087701 2,1 E E 0 - 3,0 0 - 5,0 MS 40
087702 F F 0 - 3,0 0 - 5,0
087706 2,5 F F 0 - 6,0 0
*) For saturated steam up to 143°C ( refer to performance curve for fluids on page 1)
additional versions on request

Technical data

  • Type solenoid valve
  • Construction single chamber straight valve
  • Ways 2/2-way
  • mode of operation direct acting
  • Function NC (normally closed)
  • Fitting position any
  • Media neutral gases,
  •   Cold and heated potable water and physically and chemically similar media
  • T-Medium 5 - 98 °C
  •   5 - 143 °C (3 bar) Saturated steam (289.4 °F (43.5 psi))
  • T-Ambient 5 - 60 °C
  • DN, Flow factor Kv, p-Operating see Options
  • Coil type MS 39
  •   MS 40
  • Nominal voltage 12 V DC
  •   24 V DC
  •   other voltages on request
  • Voltage tolerance +10% -15%
  • Duty cycle 100%
  • Duty cycle (Saturated steam) 50% (0,5 min On / 0,5 min Off) with Coil 8,3 W
  • Nominal power 8,0 W
  • Protection type IP 00
  • Protection Type IP 65
  • Coil connections flat tap 6,3 x 0,8 mm
  • Coil connections (MS.040) plug socket, model B-industry form
  • Insulation class H according to EN 60730
  • Protection class I according to EN 60730
  •   (for incorporation in class I)

Materials

  • Valve body PPSU
  • Plunger Guide Stainless steel
  • Plunger Stainless steel
  • Sealings EPDM
  • Coil coating PET
Technical inquiry
Technical inquiry

A. u. K. Müller GmbH & Co. KG

Dresdener Straße 162
D - 40595 Düsseldorf 

Telefon: +49 211 73 91-0
Telefax: +49 211 73 91-281

E-Mail: info(at)akmueller.de

 

A.K. Muller (UK) Ltd.
Unit 4, Brookside Business Park
Brookside Avenue, Rustington
GB - West Sussex BN16 3LP

Tel: +44 1903 788 888
Fax:+44 1903 785 817

E-Mail: valves(at)akmuller.co.uk

 

A.K. Müller France
10 Avenue du Gué Langlois
Z.A.E du Gué Langlois
F-77600  Bussy Saint Martin

Telefon: +33 1 64 62 95 14
Telefax: +33 1 64 62 95 12

E-Mail: info(at)akmuller.fr

 

 

A. u. K. Müller Shanghai
Rm26D, Huadu Mansion,
Zhangyang Rd. 838,
Shanghai, 200122, China

Telefon: +86 21 58 20 40 80
Telefax:  +86 21 58 20 42 12

E-Mail: info(at)akmueller.de

 

 

©2024 Copyright A. u. K. Müller GmbH & Co. KG