61.010.126

Control Process DN 10

Control system consisting of a proportional valve with a nominal diameter of DN 10 and a cable plug with corresponding electronics. The controlled system can be used optimally with the upstream measuring turbine
MT 40. The controlled system is used for the continuous control of volume flows and is suitable for drinking water and physically and chemically similar media.
The valve is normally closed (NC).

The data determined in the measuring turbine, is forwarded to the control electronics. The coil current is modulated via pulse width modulation (PWM) of the electronics. The modulation of the current and thus of the magnetic field causes a continuous raising or lowering of the valve core. This electronic system therefore provides an adjustable volume flow.

The electrical operational safety is guaranteed by the electrical insulation coordination, which corresponds to the VDE 110 regulations. The manufacturing process includes a 100% electrical safety test in accordance with the VDE 0631 Part 1000 regulations.

Due to the use of high-quality insulating materials, continuous operation (100% ED) is possible even at high ambient and media temperatures. The solenoid valve with glass-fibre reinforced polyamide housing is suitable for hot water.
The valve can only be operated with the appliance inletsupplied by A.u.K. Müller.

Control and Regulating Valves, Flow Sensors, Metrology 61.010 NC (normally closed) 10 bar 24 l/min

Applications

  • Thermostatically controlled heating system
  • Industrial appliances
  • Cooling and water circuits

Characteristics

  • Continuous volume flow within the control range
  • Electronics expandable e.g. flow control to a temperature setpoint
  • Normally closed (NC)
  • Suitable for hot water up to 90°C
  • Optimized water hammer characteristic by low noise emission according to EN 60730
  • High operating safety through the use of high quality materials and 100% final testing of the products

Technical data

  • Type servo solenoid valve with electronics
  • Construction 2/2-way; single chamber straight valve; servo-controlled;
  • Function NC (normally closed)
  • Fitting position any, preferably coil pointing upward
  • Media Cold and heated potable water and physically and chemically similar media
  • Pressure range 0,5 - 10,0 bar
  • Flow factor Kv 24 l/min @ 1 bar
  • Coil Type MS 42
  • Nominal voltage 24 V DC
  •   other voltages on request
  • Duty cycle 100%
  • Nominal power 11 W
  • Insulation class H according to EN 60730

Materials

  • Valve body PA 66, glass fibre reinforced
  •   PA 6/6 on request
  •   PPO on request
  • Plunger Guide Stainless steel
  • Plunger and spring stainless steel
  • Membrane and sealings EPDM
  •   VMQ (on request)
  •   NBR (on request)
  • Coil coating epoxy resin
  • Filter stainless steel (in inlet)
  •   POM on request

A. u. K. Müller GmbH & Co. KG

Dresdener Straße 162
D - 40595 Düsseldorf 

Telefon: +49 211 73 91-0
Telefax: +49 211 73 91-281

E-Mail: info(at)akmueller.de

 

A.K. Muller (UK) Ltd.
Unit 4, Brookside Business Park
Brookside Avenue, Rustington
GB - West Sussex BN16 3LP

Tel: +44 1903 788 888
Fax:+44 1903 785 817

E-Mail: valves(at)akmuller.co.uk

 

A.K. Müller France
10 Avenue du Gué Langlois
Z.A.E du Gué Langlois
F-77600  Bussy Saint Martin

Telefon: +33 1 64 62 95 14
Telefax: +33 1 64 62 95 12

E-Mail: info(at)akmuller.fr

 

 

A. u. K. Müller Shanghai
Rm26D, Huadu Mansion,
Zhangyang Rd. 838,
Shanghai, 200122, China

Telefon: +86 21 58 20 40 80
Telefax:  +86 21 58 20 42 12

E-Mail: info(at)akmueller.de

 

 

©2026 Copyright A. u. K. Müller GmbH & Co. KG