UPS-01.-

Flush mounted switching power supply

Flush mounting power supply for infrared sensors.

The power supply allows the operation of up to five sensor / valve units simultaneously.
On the primary side, two power lines (L & N) are potted to prevent the risk of electric shock.
On the secondary side, screw terminals allow the flexibility of choosing the correct cabling for the sensor / valve units.
An electronic short circuit protector is provided which automatically reverts to the normal function when the cause of the short circuit is removed.

In the flush mounted power supply there is no energy storage, so for failsafe operation, it is recommended to use the SC2 cable for each sensor / valve unit. This has a built in energy store that provides a closing pulse to the valve in the event of a power failure.
For other connections our SC1 cables are recommended.

Accessories Sanitary Valves / Electronics UPS-01

Applications

  • Supply of up to five sensor / valve units
  • Flush mounting in municipal facilities

Characteristics

  • Flush mounted switching power supply
  • Wide voltage range on the primary side (90-264VAC / 47-63Hz)
  • Secondary output (12V DC ± 5%) with built-in short circuit protection
  • Potted in durable polycarbonate housing (V0)
  • Efficiency class V
  • Max. Power 20 W

Technical data

  • Dielectric Strength 4242 VDC, primary to secondary
  • Protection type IP 00
  • Weight 155 g
  • Primary
  • Rated AC input voltage 100 - 240 V AC
  • Input working voltage 90 - 264 V AC
  • Nominal frequency 50 - 60 Hz
  • Operating frequency 47 - 63 Hz
  • AC input current max. 600 mA
  • Input protection Protection in phase (l) and neutral (N)
  • Inrush current 30 A max. cold start at 240 V input voltage
  • Operating temperature 0 - 40 °C
  • Storage temperature -10 – 80 °C (14 – 176 °F)
  • Humidity at operation 0 – 90 % RH
  • Humidity at storage 0- 90 % RH
  • Type Flush-mounted switching power supply
  • Efficiency classification V
  • Input wires 2 x 200 mm stranded UL style 1015 neutral - blue line - brown
  • Protection Internal, potted fuse, not exchangeable
  • Output
  • Output voltage 12 V DC ± 5%
  • Output current 0 – 1,67 A
  • Output rating 20 W max.
  • Ripple limit 1 % of output voltage
  • Short circuit protection Electronically protected, automatic recovery function
  • Overvoltage protection 15 V max.
  • Output connector 2 position terminal block

Materials

  • Body PC 66 UL 94: V0

A. u. K. Müller GmbH & Co. KG

Dresdener Straße 162
D - 40595 Düsseldorf 

Telefon: +49 211 73 91-0
Telefax: +49 211 73 91-281

E-Mail: info(at)akmueller.de

 

A.K. Muller (UK) Ltd.
Unit 4, Brookside Business Park
Brookside Avenue, Rustington
GB - West Sussex BN16 3LP

Tel: +44 1903 788 888
Fax:+44 1903 785 817

E-Mail: valves(at)akmuller.co.uk

 

A.K. Müller France
10 Avenue du Gué Langlois
Z.A.E du Gué Langlois
F-77600  Bussy Saint Martin

Telefon: +33 1 64 62 95 14
Telefax: +33 1 64 62 95 12

E-Mail: info(at)akmuller.fr

 

 

A. u. K. Müller Shanghai
Rm26D, Huadu Mansion,
Zhangyang Rd. 838,
Shanghai, 200122, China

Telefon: +86 21 58 20 40 80
Telefax:  +86 21 58 20 42 12

E-Mail: info(at)akmueller.de

 

 