IRS-WT-x.-

Multi-Function-Sensor, Automatic Voltage Detection, Faucet

Opto-electronic sensor unit available for use with bi stable cartridge valves having a nominal voltage of 6 VDC (e.g. 50.007.101, see separate data sheet) to be integrated within faucets.
None contact activation by IR proximity sensor.

A LED flashes each time to signal that the detection area has been entered or left.

Compact design for easy integration of sensor at minimum required space.
The minimised power consumption allows, using common batteries, a surpassing long durability and safe operation.
Individual settings may be achieved by an optional IR-remote control. (Detection range, ON- OFF, mode dependent flushing times).
Easy assembly, service and check of battery.

The sensor may be equipped with an optional push-button, which starts the flow of water immediately.

Accessories Sanitary Valves / Electronics IRS-WT-x

Applications

  • Control unit for sanitary faucets
  • Flushes
  • Irrigation systems
  • Industrial appliances

Characteristics

  • External IR-sensor with micro controller
  • Compact design
  • Voltage recognition 6V , 9V (battery) or 12V (power supply) or power supply (12V)
  • Check and switch off in case of low battery voltage or mains power failure (with power supply IRS-PS-U only)
  • Battery low voltage signal
  • Low quiescent current for elongated battery lifetime
  • Easy to assemble and service
  • Short response time on detection of user
  • Automatic detection range adjustment to environment on Power-On for 30 minutes
  • Resin moulded electronic, protection type IP 65
  • High operating safety through the use of high quality materials and 100% final testing of the products
  • Default values changeable by optional available remote control

Options

Default Settings Optional Settings with
IRS-RC3 Remote Control
 IRS-WT
Faucet
Response time <= 0,5 s -
Detection range 260 mm ± 15%
(10.24 in)
w/o  IR-window
40 - 300 mm
(1.57 - 11.81 in)
Turn off delay 1 s (± 0,5 s) 0,5 - 8,0 s
Max. time of flow 120 s (± 25 %) -
Enforced flush alle 24 h (Flushing time about 5 seconds) 24 h, 72 h, OFF
Permanent - OFF - enable / disable
Optional push button to start an immediate flow procedure available.
 IRS-WT-E
Faucet Eco Mode
Response time <= 0,5 s -
Detection range 260 mm ± 15%
(10.24 in)
w/o  IR-window
40 - 300 mm
(1.57 - 11.81 in)
Abschaltverzögerung 1 s (± 0,5 s) -
Max. time of flow 3 s (± 0,5 s) 1 - 80 s
Enforced flush alle 24 h (Flushing time about 5 seconds) 24 h, 72 h, OFF
Permanent - OFF - enable / disable
Optional push button to start an immediate flow procedure available.
 IRS-WT-OF
Faucet ON / OFF
Response time <= 0,5 s -
Detection range 80 mm ± 15%
(3.15 in)
w/o  IR-window
40, 80, 120, 160 mm
(1.57, 3.15, 4.72 or 6.30 in)
Max. time of flow 120 s (± 25 %) 10 - 310 s
Enforced flush Off 24 h, 72 h, OFF
Permanent - OFF - enable / disable
Optional push button to start an immediate flow procedure available.
 
 
Standard cable length
Valve With twin strand (red/blue)
and female connector

252 +10 mm
(9.92 +0.4 in)

Battery With twin strand (red/black)
and male connector
187 +10 mm
(7.36 +0.4 in)
Please contact us for a specific request.

Technical data

  • Type opto electronical IR-sensor
  • T-Ambient 5 - 60 °C
  • ----------------------------- -----------------------------
  • Nominal voltage 6 V DC (battery)
  • Operating voltage 5,0 - 6,0 V DC open/close
  • Signal of low voltage level &lt;5,0 V DC LED flashing
  •   &lt;4,7 V DC LED persistent signal, valve will be closed permanently
  • ----------------------------- -----------------------------
  • Nominal voltage 9 V DC (battery)
  • Operating voltage 5,7 - 9,0 V DC open/close
  • Signal of low voltage level &lt;5,7 V DC LED flashing
  •   &lt;4,7 V DC LED persistent signal, valve will be closed permanently
  • ----------------------------- -----------------------------
  • Nominal voltage 12 V DC (power supply)
  • Operating voltage 11,0 - 12,0 V DC open/close
  • Signal of low voltage level &lt;11,0 V DC LED persistent signal, valve will be closed permanently
  • ----------------------------- -----------------------------
  • Voltage recognition Battery (6V or 9V): on each output pulse or every 24 h Power supply: every 0,5 sec
  • Output voltage 5 V DC
  • Pulse shape/-time rectangular / 15 ms
  • Output current max. 800 mA
  • Protection type IP 65 according to EN 60529
  • 050-B07-060 or 50.007.100 (6 V DC only, see separate data sheet) Other valves on request.
  • Lifetime of valve min. 250.000 cycles / 5 years
  • Lifetime of battery 6 V Lithium (min. 1.300 mAh) approx. 4 years for 150 cycles / day
  •   9V Alkaline (min. 600 mAh) approx. 2,5 years at 150 cycles / day

Materials

  • Housing POM
  • IR-windows PC
  • Resilient clip PC
  • Window strip EP cellular rubber
Technical inquiry
Technical inquiry

A. u. K. Müller GmbH & Co. KG

Dresdener Straße 162
D - 40595 Düsseldorf 

Telefon: +49 211 73 91-0
Telefax: +49 211 73 91-281

E-Mail: info(at)akmueller.de

 

A.K. Muller (UK) Ltd.
Unit 4, Brookside Business Park
Brookside Avenue, Rustington
GB - West Sussex BN16 3LP

Tel: +44 1903 788 888
Fax:+44 1903 785 817

E-Mail: valves(at)akmuller.co.uk

 

A.K. Müller France
10 Avenue du Gué Langlois
Z.A.E du Gué Langlois
F-77600  Bussy Saint Martin

Telefon: +33 1 64 62 95 14
Telefax: +33 1 64 62 95 12

E-Mail: info(at)akmuller.fr

 

 

A. u. K. Müller Shanghai
Rm26D, Huadu Mansion,
Zhangyang Rd. 838,
Shanghai, 200122, China

Telefon: +86 21 50 34 23 61
Telefax:  +86 21 58 20 42 12

E-Mail: info(at)akmueller.de

 

 

©2022 Copyright A. u. K. Müller GmbH & Co. KG