Shut-off valve with hexagon socket 8 mm

The manual shut-off valve allows a complete shut-off of water paths for service e.g. pipe parts or other distribution circuits. The functionality according to DIN EN 13828 is confirmed by an accredited laboratory.
The shut-off valve ensures a tight seal so that no pressure loss in the system occurs while still in operation. Thus the main applications are where the fluid path is to be shut off for service purposes (replacement of components) or for safety.

The manual shut-off is performed using a commercially available 8 mm Allen key (52.009.100) or a pre-installed handle (52.009.200).

The shut-off valve is available with various connectors.

Accessories (other) 52.009 10 bar 57 l/min

Applications

  • In supply pipes for domestic and industrial appliances
  • Commercial Warewashing
  • Commercial kitchens technology
  • Disinfection equipment
  • laboratory equipment
  • Dental appliances
  • Irrigation systems
  • Dosing systems
  • Car washes

Characteristics

  • Tight seal, no pressure loss in the system while still in operation
  • Function in accordance to 13828, confirmed by an accredited laboratory
  • Simple shut off by 8 mm Allen key or convenient operation due to pre-assembled handle
  • Maintenance-free shut-off cylinder
  • Free flow in accordance with nominal orifice DN 9
  • Suitable for hot water up to 90°C
  • Easy to clean
  • Pressure resistant up to 10 bar
  • Long term performance capability
  • High operating safety through the use of high quality materials and 100% final testing of the products

Options

Zulauf Auslauf Länge ID
Ø A A1 Ø B B1 C L L1
G 3/4 17,5 G 3/4 innen 10,5 35 66,5 77 60450
G 1/2 innen 9 G 1/2 14,5 29,5 64,5 73,5 60452
G 1/2 14,5 G 3/8 innen 7,7 25 61,5 69,2 60453
G 1/2 innen 9 G 3/8 12,5 29,5 62,5 71,5 60454
3/4 - 11,5 NH 17,5 3/4 - 11,5 NH innen 10,5 35 66,5 77 60455
G 3/4 innen 10,5 G 3/4 17,5 35 66,5 77 auf Anfrage
G 1/2 14,5 G 1/2 innen 9 29,5 64,5 73,5 auf Anfrage

Technical data

  • Type Stopcock
  • Construction single chamber straight valve
  • Function Manually
  • Fitting position any
  • Media Cold and heated potable water and physically and chemically similar media
  • T-Medium 5 - 90 °C (194 °F max.)
  • T-Ambient 5 - 60 °C
  • DN 9 mm
  • Pressure range 0 - 10 bar
  • Flow factor Kv 57 l/min @ 1 bar
  • Flow regulator on request

Materials

  • Valve body PA 66, glass fibre reinforced
  • Stopcock PPE
  •   Stainless steel on request
  • Stopper POM
  • Sealings EPDM
  • Filter (in inlet) POM
  •   stainless steel on request
Technical inquiry
Technical inquiry

A. u. K. Müller GmbH & Co. KG

Dresdener Straße 162
D - 40595 Düsseldorf 

Telefon: +49 211 73 91-0
Telefax: +49 211 73 91-281

E-Mail: info(at)akmueller.de

 

A.K. Muller (UK) Ltd.
Unit 4, Brookside Business Park
Brookside Avenue, Rustington
GB - West Sussex BN16 3LP

Tel: +44 1903 788 888
Fax:+44 1903 785 817

E-Mail: valves(at)akmuller.co.uk

 

A.K. Müller France
10 Avenue du Gué Langlois
Z.A.E du Gué Langlois
F-77600  Bussy Saint Martin

Telefon: +33 1 64 62 95 14
Telefax: +33 1 64 62 95 12

E-Mail: info(at)akmuller.fr

 

 

A. u. K. Müller Shanghai
Rm26D, Huadu Mansion,
Zhangyang Rd. 838,
Shanghai, 200122, China

Telefon: +86 21 58 20 40 80
Telefax:  +86 21 58 20 42 12

E-Mail: info(at)akmueller.de

 

 

©2024 Copyright A. u. K. Müller GmbH & Co. KG