IRS-UWS-xb.

Multi-Function-Sensor,Automatic Voltage Detection, Urinal, WC, Shower

Opto-electronic sensor unit available for use with bistable cartridge valves having a nominal voltage of 6 VDC (e.g. 50.007.101, see separate data sheets) for use for urinal, toilet (WC) or shower.
As an option, the sensors can also be supplied pre-set at the factory for monostable cartridge valves up to a maximum of 12 V DC.

Compact design for easy integration of sensor at minimum required space.
The minimised power consumption allows, using common batteries, a surpassing long durability and safe operation.
Individual settings may be achieved by an optional IR-remote control. (detection range, ON- OFF, follow-up-time).
Easy assembly, service and check of battery.

The sensor can optionally be fitted with a button connected to a cable, which can be used to start the immediate flow of water.

Accessories Sanitary Valves / Electronics IRS-UWS-xb

Applications

  • Control unit for sanitary urinals, WC's and Showers
  • Flushes
  • Irrigation systems
  • Industrial appliances

Characteristics

  • External IR-sensor with micro controller
  • Compact design
  • Voltage recognition 6V , 9V (battery) or 12V (power supply) or power supply (12V)
  • Check and switch off in case of low battery voltage or mains power failure (with power supply IRS-PS-U only)
  • Battery low voltage signal
  • Low quiescent current for elongated battery lifetime
  • Easy to assemble and service
  • Short response time on detection of user
  • Automatic detection range adjustment to environment on Power-On for 30 minutes
  • Resin moulded electronic, protection type IP 65
  • Shower functionality with two modes BDM = body detection mode HDM = hand detection mode
  • High operating safety through the use of high quality materials and 100% final testing of the products
  • Default values changeable by optional available remote control

Options

Technical data

  • Type opto electronical IR-sensor
  • T-Ambient 5 - 60 °C
  • ----------------------------- -----------------------------
  • Nominal voltage 6 V DC (battery)
  • Operating voltage 5,0 - 6,0 V DC open/close
  • Low voltage level < 5,55 V DC LED flashing
  •   < 5,45 V DC LED persistent signal, valve will be closed permanently
  • ----------------------------- -----------------------------
  • Nominal voltage 9 V DC (battery)
  • Operating voltage 5,7 - 9,0 V DC open/close
  • Signal of low voltage level <5,7 V DC LED flashing
  • Low voltage level < 5,4 V DC LED persistent signal, valve will be closed permanently
  • ----------------------------- -----------------------------
  • Nominal voltage 12 V DC (power supply)
  • Operating voltage 11,0 - 12,0 V DC open/close
  • Signal of low voltage level <11,0 V DC LED persistent signal, valve will be closed permanently
  • ----------------------------- -----------------------------
  • Voltage recognition Battery (6V or 9V): on each output pulse or every 24 h Power supply: every 0,5 sec
  • Output voltage 5 V DC
  • Pulse shape/-time rectangular / 15 ms
  • Output current 830 mA
  • Protection type IP 65 according to EN 60529
  • 050-B07-060 or 50.007.100 (6 V DC only, see separate data sheet) Other valves on request.
  • Lifetime of battery 6 V Lithium (min. 1.300 mAh) approx. 4 years for 150 cycles / day
  •   9V Alkaline (min. 600 mAh) approx. 2,5 years at 150 cycles / day

Materials

  • Housing POM
  • IR-windows PC
  • Resilient clip PC
  • Window strip EP cellular rubber

A. u. K. Müller GmbH & Co. KG

Dresdener Straße 162
D - 40595 Düsseldorf 

Telefon: +49 211 73 91-0
Telefax: +49 211 73 91-281

E-Mail: info(at)akmueller.de

 

A.K. Muller (UK) Ltd.
Unit 4, Brookside Business Park
Brookside Avenue, Rustington
GB - West Sussex BN16 3LP

Tel: +44 1903 788 888
Fax:+44 1903 785 817

E-Mail: valves(at)akmuller.co.uk

 

A.K. Müller France
10 Avenue du Gué Langlois
Z.A.E du Gué Langlois
F-77600  Bussy Saint Martin

Telefon: +33 1 64 62 95 14
Telefax: +33 1 64 62 95 12

E-Mail: info(at)akmuller.fr

 

 

A. u. K. Müller Shanghai
Rm26D, Huadu Mansion,
Zhangyang Rd. 838,
Shanghai, 200122, China

Telefon: +86 21 58 20 40 80
Telefax:  +86 21 58 20 42 12

E-Mail: info(at)akmueller.de

 

 

©2024 Copyright A. u. K. Müller GmbH & Co. KG